Features

  • Choice of 3 cabinet sizes (Compact, Active, Xtend) to maximise battery runtime

  • 96.5% operating efficiency (ONLINE mode) reduces energy waste

  • High overload and short circuit capacity guarantees availability

  • Designed to handle non-linear loads so ideal for blade servers

  • Reduces harmonic voltage distortion (<1% at resistive load and < 1.5% at non-linear load)

  • Parallel up to 8 UPS for extra capacity or redundancy

  • Large 5-inch colour touchscreen display shows UPS status, load, and battery level

  • LED indicator automatically changes colour depending on the UPS’s status

10 kVA - 120 kVA

Email: sale@theupsteam.co.uk
Web Form

Enquire About The

Email: sale@theupsteam.co.uk
Web Form

Sentryum

Range

Riello Sentryum Range

S3M CPT 10

Online -- 10kVA - 1 Level Of Backup Time

1:1 / 3:1

S3M ACT 10

Online -- 10kVA - 2 Levels Of Backup Time

1:1 / 3:1

S3M XTD 10

Online -- 10kVA - 3 Levels Of Backup Time

1:1 / 3:1

S3M CPT 15

Online -- 15kVA - 1 Level Of Backup Time

1:1 / 3:1

S3M ACT 15

Online -- 15kVA - 2 Levels Of Backup Time

1:1 / 3:1

S3M XTD 15

Online -- 15kVA - 3 Levels Of Backup Time

1:1 / 3:1

S3M CPT 20

Online -- 20kVA - 1 Level Of Backup Time

1:1 / 3:1

S3M ACT 20

Online -- 20kVA - 2 Levels Of Backup Time

1:1 / 3:1

S3M XTD 20

Online -- 20kVA - 3 Levels Of Backup Time

1:1 / 3:1

S3T CPT 10

Online -- 10kVA - 1 Level Of Backup Time

3:3

S3T ACT 10

Online -- 10kVA - 2 Levels Of Backup Time

3:3

S3T XTD 10

Online -- 10kVA - 3 Levels Of Backup Time

3:3

S3T CPT 15

Online -- 15kVA - 1 Level Of Backup Time

3:3

S3T ACT 15

Online -- 15kVA - 2 Levels Of Backup Time

3:3

S3T XTD 15

Online -- 15kVA - 3 Levels Of Backup Time

3:3

S3T CPT 20

Online -- 20kVA - 1 Level Of Backup Time

3:3

S3T ACT 20

Online -- 20kVA - 2 Levels Of Backup Time

3:3

S3T XTD 20

Online -- 20kVA - 3 Levels Of Backup Time

3:3

S3T ACT 30

Online -- 30kVA - 2 Levels Of Backup Time

3:3

S3T XTD 30

Online -- 30kVA - 3 Levels Of Backup Time

3:3

S3T ACT 40

Online -- 40kVA - 2 Levels Of Backup Time

3:3

S3T XTD 40

Online -- 40kVA - 3 Levels Of Backup Time

3:3

S3T ACT 60

Online -- 60kVA -- No Internal Batteries

3:3

S3T XTD 60

Online -- 60kVA - 3 Levels Of Backup Time

3:3

S3T 80

Online -- 80kVA -- No Internal Batteries

3:3

S3T 100

Online -- 100kVA -- No Internal Batteries

3:3

S3T 120

Online -- 120kVA -- No Internal Batteries