Salicru's SPS ADVANCE RT2 series is a range of UPS featuring line-interactive technology with sine-wave output voltage and convertible tower/rack format, the height being only 2U for all power ratings. In addition, its output power factor of 0.9 and compatibility with APFC (active power factor correction) type loads make it the best option for any type of load that requires protection.
In terms of communications, it features an RS-232/USB interface (compatible with HID protocol) and a smart slot that can optionally hold an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of protected devices.
And other outstanding features include: solutions for applications with long backup (by means of equipment with extra chargers and additional battery modules), swivel mount display and adapters (pedestal and lugs) for placing in tower or rack formats and programmable outputs (critical/non-critical loads) to extend the available backup.
Technical Specifications
TECHNOLOGY - Line-interactive
FORMAT - Convertible tower/rack (2U)
INPUT
Rated voltage - 208 / 220 / 230 / 240 V
Voltage range 100% load - 170 ÷ 280 V
Stabiliser - AVR (Buck & Boost)
Rated frequency - 50 / 60 Hz (auto-detection)
Frequency range - ±5 Hz
Auto~detection of frequency - Yes
Protection - Fuse (800/1100) or resettable thermal cutoff (1500/2000/3000)
OUTPUT
Power factor - 0.9
Rated voltage - 208 / 220 / 230 / 240 V
Voltage accuracy (battery mode) - ±1.5%
Power (VA/W) - 1100 / 990
Total harmonic distortion (THDv) - < 2% linear load / < 5% non-linear load
Waveform (battery mode) - Pure sine wave
Frequency - 50/60 Hz (same as input)
Frequency accuracy (battery mode) - ±0.1Hz
Admissible overloads in battery mode - < 120% off at 1 min / < 150% off at 10 s
Admissible overloads in-line mode - < 120% off at 5 min / < 150% off at 10 s / >150 %: 1 s
Socket type - IEC
No. Of sockets - 8
Programmable sockets - Yes, for critical / non-critical loads (4/4)
BATTERY
Battery type - Pb-Ca sealed, AGM, maintenance-free
Charge type - I/U (constant current/constant voltage)
Recharge time - 4 hours to 90%
Battery test - Automatic on every start + one x week
CHARGER
Temperature voltage compensation - Yes
COMMUNICATION
Ports - RS-232/USB-HID
Intelligent slot - Slot for SNMP/potential-free contacts/ MODBUS
Monitoring software - For Windows, Linux and Mac
INDICATIONS
Type - LCD + keypad
Values - Voltage, power and input and output frequency / Battery voltage / % battery charge / % load / Operating mode / Fault / Discharge time / Mute
Operating modes - Normal / Stabilisation (AVR) / Battery / Fault
Alarm - Output battery mode, polarity, low battery (back up time), charger failure and overload
Audible - Every 10 s for battery operation. Every 2 s for low battery / Polarity. Every 1 s for overcharge. Continuous for fault.
Failure - Display LCD
OTHER FUNCTIONS
Cold start (start-up from batteries) - Yes
Emergency stop (EPO) - Yes
ADSL/fax/modem transient protector - Yes
Green-function - Yes, automatic stop in battery mode with load <5%
Smart fan speed - Yes, smart control of fan speed
Site wiring fault - Yes, error detection of phase-neutral rotation and/or absence of earth
GENERAL
Operating temperature - 0º C ÷ 40º C
Relative humidity - Up to 95%, non-condensing
Maxium operating altitude - 2,400 masl (power degradation up to 5,000 m)
Acoustic noise at 1 metre - < 45dB
STANDARDS
Safety - EN-IEC 62040-1
Electromagnetic compatibility (EMC) - EN 62040-2:2006(C2)
Operation - EN 62040-3:2011
Quality and environmental management - ISO-9001 & ISO-14001
DIMENSIONS
Depth (mm) - 410
Width (mm) - 438
Height (mm) - 88