top of page

SPS 3000 ADV T B1

Buy Now

Email: sale@theupsteam.co.uk
Web Form

Enquire About The

Email: sale@theupsteam.co.uk
Web Form

SPS 3000 ADV T B1

UPS

Description

Salicru's SPS ADVANCE T series offers, as a UPS solution, optimum levels of efficiency and reliability for all critical devices that require power supply continuity and dependability. They come in a very compact tower format to save space in server and computer rooms. They also feature line-interactive technology to combat any fluctuations in the mains supply together with an output voltage that is always sine-wave, the highest quality possible to power all sensitive loads.

For easier and more convenient use, they feature a display that shows all necessary information on the operation of the device and power supply (input/output voltage, % load, % battery, etc.) and a wide range of communication options through the USB interface with HID protocol, monitoring and management software (downloadable) and integrated smart slot (SNMP).

Also noteworthy is their compatibility with current APFC (active power factor correction) power supplies.
The power range for the SPS ADVANCE T series is: 850, 1,000, 1,500, 2,000 and 3,000 VA.

Technical Specifications

TECHNOLOGY - Line-interactive


FORMAT - Tower


INPUT

Rated voltage - 230 V

Voltage range 100% load - 165 ÷ 290 V

Stabiliser - AVR (Buck & Boost)

Rated frequency - 50 / 60 Hz (auto-detection)

Frequency range - ±5 Hz

Auto~detection of frequency - Yes

Protection - Resettable breaker


OUTPUT

Rated voltage - 230 V

Voltage accuracy (battery mode) - ±10%

Power (VA/W) - 3000 / 2100

Total harmonic distortion (THDv) - <5%

Waveform (battery mode) - Pure sine wave

Frequency - 50/60 Hz (same as input)

Frequency accuracy (battery mode) - ±1 Hz

Compatibility with APFC loads - Yes (1)

Performance Stabiliser mode (AVR) - >92%

Performance Battery mode - >80%

Admissible overloads in battery mode - 110% for 1 min / >130% immediate

Socket type - IEC C13

No. Of sockets - 4


BATTERY

Battery type - Pb-Ca sealed, AGM, maintenance-free

Charge type - I/U (constant current/constant voltage)

Recharge time - 4 hours to 90%

Battery test - Automatic on each start-up + manual


COMMUNICATION

Ports - RS-232 / USB (HID)

Intelligent slot - Slot for SNMP/potential-free contacts/ MODBUS

Monitoring software - For Windows, Linux and Mac


INDICATIONS

Type - LCD + keypad

Values - Input and output voltage / % load / % battery / backup

Levels - Connected load / overload / battery / low battery

Operating modes - Normal / Stabilisation (AVR) / Battery / Fault

Alarm - Battery / low battery / overload / failure

Audible - Every 30 s for battery operation. Every 2 s for low battery / Polarity. Every 0,5 s for overcharge. Continuous for fault.

Failure - Display LCD


OTHER FUNCTIONS

Cold start (start-up from batteries) - Yes

Emergency stop (EPO) - Yes


GENERAL

Operating temperature - 0º C ÷ 40º C

Relative humidity - Up to 95%, non-condensing

Maxium operating altitude - 2,400 masl

Acoustic noise at 1 metre - <45 dB (2)


STANDARDS

Safety - EN-IEC 62040-1

Electromagnetic compatibility (EMC) - EN 62040-2

Operation - EN 62040-3

Quality and environmental management - ISO 9001 & ISO 14001


DIMENSIONS

Depth (mm) - 416

Width (mm) - 196

Height (mm) - 342


WEIGHT - Weight (kg)

22,16


(1) Power degradation of 20%

(2) <50 dB for 3000 VA model